Back Products

AWM 2919

  • Product Describe
  • Product Detail
  • Construction Stranded, tinned or bare copper conductor 
    -First type core: mini-coaxial cable with PE insulation 
    -Second type core: PVC insulation 
    Tinned or bare stranded copper drain wire 
    Tinned or bare copper wire braid shield 
    PVC jacket
    Standard UL Subject 758, UL1581 & CSA C22.2 No.210.2
    Passes UL VW-1 & CSA FT1 vertical flame test
    Technical Data Rated Temperature-80
    Rated Voltage-30V
  • Part No. Core Numbers Conductor Size Conduct Construction Insulation Thickness Insulation Dia. Spiral Structure Covering Dia. Overall Shielding Material Overall Shield Coverage O.D. Maximum Resistance at 20 
    Num (AWG/MCM) (Num/mm) (mm) (mm) (Num/mm) (mm) (mm) % (Ω/km)
    2919-201 1CXUL1354 4CXUL1061  28 24  7/0.127 7/0.20  0.61 0.26  1.60 1.12  42/0.12  2.55 AL  0.9 7.9 223 88.9 
    2919-202 3CXUL1354 4CXUL1061  28 24  7/0.127 7/0.20  0.61 0.26  1.60 1.12  42/0.12  2.55 AL  0.9 8 223 88.9 
    2919-203 3CXUL1354 5CXUL1061  28 24  7/0.127 7/0.20  0.61 0.26  1.60 1.12  42/0.12  2.55 AL  0.87 8 223 88.9 
    2919-204 3CXUL1354 6CXUL1061  28 26  7/0.127 7/0.16  0.61 0.26  1.60 1.00  42/0.12  2.55 PAPER  0.8 7.9 223 139 
    2919-205 3CXUL1354 6CXUL1061  28 24  7/0.127 7/0.20  0.61 0.26  1.60 1.12  42/0.12  2.55 AL  0.85 8 223 88.9 
    2919-206 3CXUL1354 7CXUL1061  30 28  7/0.10 7/0.127  0.50 0.26  1.30 0.90  39/0.1  2.55 AL  0.895 7.2 354 223 
    2919-207 3CXUL1354 7CXUL1061  28 24  7/0.127 7/0.20  0.61 0.26  1.60 1.12  42/0.12  2.55 AL  0.85 8 223 88.9