Back Products

AWM2468

  • Product Describe
  • Product Detail
  • Construction Tinned or bare, stranded or solid copper conductor, 32-16 AWG minimum
    PVC jacket
    Standard UL Subject 758, UL1581 & CSA C22.2 No.210.2
    Passes UL VW-1 & CSA FT1 vertical flame test
    Technical Data Rated Temperature-80
    Rated Voltage-300V
  • Part No. Core Numbers Conductor Size Conduct Construction Conductor Dia. Insulation Thickness O.D. Maximum Resistance at 20 
    Num (AWG/MCM) (Num/mm) (mm) (mm) (mm) (Ω/km)
    2468-281 2 28 7/0.127 0.38 0.43 1.24X2.58 223
    2468-282 3 28 7/0.127 0.38 0.43 1.24X3.92 223
    2468-283 4 28 7/0.127 0.38 0.43 1.24X5.26 223
    2468-261 2 26 7/0.16 0.48 0.43 1.34X2.78 139
    2468-262 3 26 7/0.16 0.48 0.43 1.34X4.22 139
    2468-263 4 26 7/0.16 0.48 0.43 1.34X5.66 139
    2468-241 2 24 7/0.20 0.6 0.43 1.45X3.04 88.9
    2468-242 3 24 7/0.20 0.6 0.43 1.45X4.63 88.9
    2468-243 4 24 7/0.20 0.6 0.43 1.45X6.22 88.9
    2468-221 2 22 7/0.254 0.76 0.43 1.62x3.34 57.5
    2468-222 3 22 7/0.254 0.76 0.43 1.62X5.06 57.5
    2468-223 4 22 7/0.254 0.76 0.43 1.62X6.78 57.5
    2468-201 2 20 26/0.16 0.94 0.43 1.80X3.70 34.6
    2468-181 2 18 41/0.16 1.18 0.43 2.04X4.23 23.3